According to the problem analysis result done by TSA, you can directly begin the subsequent troubleshooting process from the corresponding potential root cause.
2-2-1-1 - Replace the flowmeter (seeSOP here) , and verify flowmeter functionality.
- Result 1 - The flowmeter reading is accurate.
Start 2-2-1-2. - Result 2 - The flowmeter reading is inaccurate.
Escalate to FAE.
- Result 3 - The flowmeter is not replaceable due to harsh/tiny work space.
Escalate to manager (machine swap).
2-2-1-2 - Fill tube, and make a drink to verify the dispense wrong volume issue is resolved.
- Result 1 - The drink can be made with the right volume and taste.
Issue close.
Root cause: The flowmeter fails.
- Result 2 - The dispense volume is still wrong.
Escalate to FAE.