2-2 Dispense Wrong Volume

Modified on Fri, 18 Oct, 2024 at 1:15 PM

According to the problem analysis result done by TSA, you can directly begin the subsequent troubleshooting process from the corresponding potential root cause.


2-2-1-1 - Replace the flowmeter (seeSOP here) , and verify flowmeter functionality.


  • Result 1 - The flowmeter reading is accurate. 
    Start 2-2-1-2.


  • Result 2 - The flowmeter reading is inaccurate
    Escalate to FAE.


  • Result 3 - The flowmeter is not replaceable due to harsh/tiny work space.   
    Escalate to manager (machine swap).



2-2-1-2 - Fill tube, and make a drink to verify the dispense wrong volume issue is resolved.


  • Result 1 - The drink can be made with the right volume and taste. 
    Issue close.

    Root cause: The flowmeter fails.


  • Result 2 - The dispense volume is still wrong
    Escalate to FAE.